beautypg.com

Monroe Electronics R164 User Manual

Monroe Electronics Sensors

background image

Model 3000R-164 Stereo A/V Switch Instruction Sheet

Installation


1. Connect

the

Comm outputs

on the R164 to your
equipment's inputs.

2. Connect your primary

audio/video signal sources to
the NC inputs on the R164.

3. Connect your secondary

audio/video signal sources to
the NO inputs on the R164.

4. Connect power pack wires to

the 2-position terminal block
plug provided,
WH is

+ ,

BK is GND

then plug onto header at the

rear of the unit.

5. A TTL level control signal or

a dry contact across GND
and relay Set will change the
output from the primary to
the secondary.



















P/N 1340166 (R164) 101606

Relay Connection:

Connect the normally open (NO)
contact to Set.
Connect the relay common
(COM) contact to GND.

Open Collector

:


Connect your transistor’s
collector to Set and the
transistor’s emitter to GND.


Operation

The R164’s primary (NC) inputs
are normally connected to the
common (Comm) outputs. It
remains in this state until the Set
input is connected to GND. This
will connect the secondary input
to common for the duration of the
connection.


The RESET connection is not
utilized in this unit.














Specifications

Video
75

; ‘BNC’ connectors


Audio
Balanced stereo; screw
terminals; >90 dB isolation

Isolation
@ 5 MHz
> 90 dB
@450 MHz > 58 dB

Return Loss
> 35 dB

Control Input
10 mA maximum to GND.

Power Requirement
Input: 100-240 VAC

±

2%,

50/60 Hz.
Output; +12 VDC

Physical
1.75"H x 19"W x 4"D














Design and specifications are subject to
change without notice.