Supported sample rates
44.1 - 192 kHz, internal dejittering via
sample rate converter
Digital-to-Analog Outputs
Output impedance
<40 Ohm, electronically balanced
Nominal output level
+6 dBu
Maximum output level
+18 dBu
Frequency response
+0/-0.2 dB, 2 Hz to 20 kHz
THD + noise
0.0006 % (-105 dB) typical @ 1 kHz/-1 dBfs
Dynamic range
119 dB typical, 20 Hz to 20 kHz, A-
weighted @ +18 dBu
Analog-In to Analog-Out
Frequency response
20 Hz to 20 kHz, ±0.1 dB
Dynamic range
115 dB typical, 20 Hz to 20 kHz,
unweighted
THD + noise
0.0007 % (-103 dB) typical @ 1 kHz / +17
dBu (all gains zero)
0.001 % (-100 dB) typical @ 1 kHz / +6 dBu
(all gains zero)
Conversion resolution
24 Bit
Internal sample rate
96 kHz
Internal data path
28 bit integer, arithmetic precision: 76 bit
System propagation delay
0.5 ms (analogue to analogue)
Remote Interface
RJ45 EtherCon™ connector for a
10/100Base-TX
ethernet (IP) connection
Power supply
AC
100 - 240 V~ / 50 - 60 Hz
I nom.
150 - 100 mA
Dimensions and Weight
Dimensions (W x H x D*)
1 RU rack mount: 483 x 44 x 192 mm (19"
× 1.75" × 7.6")
*installation depth incl. power cord 260