KLING & FREITAG K&F CD 44 Digital System controller User Manual
Page 20

User's manual
K&F CD 44 Digital System Controller
KLING & FREITAG GMBH © 2014
Version 11.6
Page 20 of 77
Butterworth
4th ord.
24
dB/
oct.
2
1.307
0.541
-
-
Linkwitz-
Riley
4th ord
24
dB/
oct.
2
0.707
0.707
-
-
Butterworth
5th ord.
30
dB/
oct.
3
1.618
0.618
0
-
Butterworth
6th ord.
36
dB/
oct.
3
1.932
0.707
0.518
-
Linkwitz-
Riley
6th ord.
36
dB/
oct.
3
1
1
0.5
-
Butterworth
7th ord.
42
dB/
oct.
4
2.247
0.802
0.555
0
Butterworth
8th ord.
48
dB/
oct.
4
2.563
0.9
0.601
0.51
Linkwitz-
Riley
8th ord.
48
dB/
oct.
4
1.307
1.307
0.541
0.541
5.
LowP = Low Pass Filter
20
50
100
500
1000
5000
10000
20000
-40
-36
-24
-12
-6
-3
0
2
Frequency in [Hz]
P
o
w
e
r
in
[
d
B
]
FilterType = 'LowP' (Lowpass) Freq = 1000Hz
Q = 0.707
Butterworth 1.Ordnung
Q = 0.2
Q = 0.5
Linkwitz-Riley 2.Ordnung
Q = 0.707 (default) Butterworth 2.Ordnung
This example shows various low pass filters at 1000Hz, which are characterised by
different Q-factors.