KLING & FREITAG K&F CD 44 Digital System controller User Manual
Page 38

User's manual
K&F CD 44 Digital System Controller
KLING & FREITAG GMBH © 2014
Version 11.6
Page 38 of 77
as cardioid rear,
emitting to the back
NomLS2 HC-F /
NomLT HC-F /
NomXLS HC-F /
NomXLT HC-F
Nomos LS2 / Nomos
LT / Nomos XLS /
Nomos XLT in
normal mode as
hypercardioid front,
emitting to the front
all K&F loudspeaker
NomLS2 HC-R /
NomLT HC-R /
NomXLS HC-R /
NomXLT HC-R
Nomos LS2 / Nomos
LT / Nomos XLS /
Nomos XLT in
normal mode as
hypercardioid rear,
emitting to the back
all K&F loudspeaker
NomLS2 HC-F60Hz /
NomLT HC-F60Hz /
NomXLS HC-F60Hz/
NomXLT HC-F60Hz
Nomos LS2 / Nomos
LT / Nomos XLS /
Nomos XLT in
sub-bass mode as
hypercardioid front,
emitting to the front
all K&F loudspeaker
NomLS2 HC-R60Hz /
NomLT HC-R60Hz /
NomXLS HC-R60Hz /
NomXLT HC-R60Hz
Nomos LS2 / Nomos
LT / Nomos XLS /
Nomos XLT in
sub-bass mode as
hypercardioid rear,
emitting to the back
all K&F loudspeaker
Sequenza 5:
Name LS-Block
Application
Combination with
LS-Block
S5W FR
Sequenza 5 in full-
range mode
-
S5W LCut
Sequenza 5 in low-
cut mode
all K&F Subwoofer
S5B
Sequenza 5B in
normal mode
all K&F loudspeaker
2.
Select
The LS-Block 'Flat' is a distinctive feature. It is intended for special uses such as processing
or transmitting line signals, or using third party products or Kling & Freitag speakers
where no LS-Block is available. In this LS-Block, all filters are switched off, and there is
also no subsonic filter intended! It is still possible, though, to equalise signals with the
help of the PEQs and the EQ 31 band.
When using speakers with the LS-Block 'Flat', the limiter must be set at