2.3

Installation Method

2.3.1 Compact

Basic configuration

Remove all the packaging materials and labels.

Choose a Master EE2CL unit; this can be any of the units purchased.

Connect the 48Vdc power supply to the Master EE2CL unit.

Check that the blue LEDs on both EE2CL units are lit.

Connecting the EE2CL to the camera

Mount the EE2CL near to the IP camera.

Connect an RJ45 cable between the camera and the RJ45 connector on the
EE2CL unit.

Connect the coaxial cable to the BNC connector on the EE2CL unit.

If multiple camera units connect to a single Master unit then the 1:4 BNC
Splitter Adaptor or BNC-T adapter will be required.


Note:

Depending on power requirements and cable distances power for both the Master

and Slave EE2CL units and the IP cameras can be supplied from the PSU located at the
Master EE2CL unit. For high power or long distance systems, multiple PSU units will be
required; see Section 2.6.

Connecting the Master EE2CL unit at the Control Room

Mount the Master EE2CL unit in the Control Room.

Connect the coaxial cable to the BNC connector on the EE2CL unit.

Connect the supplied 48Vdc PSU to the EE2CL unit

Connect the RJ45 cable from the EE2CL unit to the Control Room
equipment.

The green LEDs will light when a network link is established and flash to
show when data traffic is being passed.

See section 2.7 for LED status.

Note:

If two or more Master EE2CL units are connected to the same switch within a

network, the units will need to be ‘joined’ to each other. You will need a small paper-
clip partially straightened to join EE2CL units; this is provided with the unit.