KBC Networks EE2CL User Manual
Page 10

Extended Ethernet User Manual
Manual-EE2CL_Series-Rev1304.docx
Copyright © KBC Networks Ltd. 2013
Page 10 of 19
www.kbcnetworks.com
Joining EE2CL units
•
Remove all the packaging materials and labels.
•
Choose an EE2CL unit (unit ‘A’); this can be any of the units purchased.
•
Using a coaxial jumper lead, connect the chosen EE2CL unit (unit ‘A’) to one
of the other units (unit ‘B’) by attaching one EE2CL unit to each end of the
coaxial cable.
•
Connect the 48Vdc power supply to the EE2CL unit ‘A’.
•
Check that the blue LEDs on both EE2CL units are lit.
•
Wait 20 seconds. Check that the green BNC LEDs on both EE2CL are ‘off’.
Note:
If either of the green BNC LEDs remains ‘on’ then that unit has already been
‘joined’ to another EE2CL unit in a different group and will need to be ‘un-joined’ before
being ‘joined’ to the new unit. See the ‘un-joining’ instructions below.
•
On the EE2CL unit ‘A’ (which is connected to the PSU) use the straightened
paper-clip to depress the push button for 2 seconds. This button can be
found slightly above the PoE LED.
•
The blue Power LED will flash.
•
Depress the same push-button on the EE2CL unit ‘B’ for 2 seconds.
•
Wait for 10 seconds. The two units will now try to establish an encrypted
communication.
•
Once the blue Power LEDs return to a steady condition the units have been
joined.
•
If more EE2CL units need to be ‘joined’, disconnect EE2CL unit ‘B’ from
EE2CL unit ‘A’. Connect the new ‘un-joined’ EE2CL unit ‘C’ to EE2CL unit ‘A’.
•
Repeat the joining instructions until all units in the group are ‘joined’ to the
EE2CL unit ‘A’.
Un-joining EE2CL units
•
Disconnect the EE2CL unit from the old network.
•
Connect a 48vdc PSU to the unit.
•
Wait until the green BNC LED lights.
•
Using the straightened paper-clip press the small push-button located
behind and slightly above the RJ45 LED.
•
Wait until the blue LED turns off.
•
Release the paper-clip.
•
The green BNC and RJ45 LEDs will flash and then turn off.
•
The green BNC LED will then switch on for 10 seconds and then switch off.
•
The units are now un-joined.