2.3.2 Rack-mount

Remove all packaging material.

For each of the 1:4 BNC Splitter Adaptors, push the BNC connectors through

the holes in the front panel of the rack and secure into place. Ensure that

the BNC connectors are properly positioned so that they do not have contact

with the metal rack, before clamping into place.

Position the PSUs into the internal PSU brackets, they do not need to be

secured in place, ensure that the slot in the front is lined up with the PSU

mains pins.

Position the EE2CL units into the internal brackets and secure with the nuts

and bolts provided with the rack.

Attach the 1:4 BNC Splitter Adaptor to the connector on the EE2CL unit.

Connect the kettle lead through the front panel into the PSUs.

Switch the power on.

See section 2.7 for LED status.