4 installation method – KBC Networks ESML3-FL2-D4 User Manual
Page 7

Ethernet Switch User Manual
Manual_hw-ESML3-FL2-D4-Rev1011
Copyright © KBC Networks Ltd.
Page 7 of 18
www.kbcnetworks.com
2.4 Installation Method
2.4.1 DIN Rail Mount
•
Remove all packaging material.
•
Attach the device to a DIN rail.
•
Attach copper and/or fiber cables as required.
•
Insert the red sleeved wire from the supplied in-line PSU into the +ve power
input and the blue sleeved wire into the –ve power input of the green male
power block terminal and tighten the screws using the flathead screwdriver
provided.
•
Insert the male power block (attached to the supplied in-line PSU) to the
female power socket on the device and tighten the terminal locking screws
using the flathead screw driver provided.
See Section 2.8 for LED status.
2.4.2 Wall-mount
•
Remove all packaging material.
•
Unscrew the DIN rail mounting plate from the switch taking special care to
retain the 2 screws using a Phillips No.1 or No.2 screwdriver.
•
Attach the supplied wall mount plate to the switch using the 2 screws that
have just been removed from the DIN rail mounting plate with a Phillips
No.1 or No.2 screwdriver.
•
Position the unit on the required, flat surface and secure with screws via the
mounting plate holes. Screws are not provided.
•
Attach copper and/or fiber cables as required.
•
Insert the red sleeved wire from the supplied in-line PSU into the +ve power
input and the blue sleeved wire into the –ve power input of the green male
power block terminal and tighten the screws using the flathead screwdriver
provided.
•
Insert the male power block (attached to the supplied in-line PSU) to the
female power socket on the device and tighten the terminal locking screws
using the flathead screw driver provided.
See Section 2.8 for LED status.