3. INSTALLATION

Operation manual b43, chapter 3 -installation- page 3-3




The digital audio toolbox b43 can be remote-controlled by
means of parallel GPI contacts.

use :

remote-controlled changeover of presets

connector:

D-SUB 15pin, female


Pin assignments


Pin

Signal name

Logic

I/O

Functions

1

PRESET1

H

I

recall preset1

2

PRESET2

H

I

recall preset2

3

PRESET3

H

I

recall preset3

4

PRESET4

H

I

recall preset4

5

PRESET5

H

I

recall preset5

6

PRESET6

H

I

recall preset6

7

PRESET7

H

I

recall preset7

8

PRESET8

H

I

recall preset8

9

MUTE

H

I

Muting outputs

10 BYPASS

H

I bypass

on

11 not

used

12 not

used

13 not

used

14

Common pin

External ground

15

+5V

O

Test power source

Electrical specification:

GPI input

potential free by opto-coupler, low active

On:

+3.5…+30V between GPI input

and

pin14

Off:

less then 1.5V, min. 50ms

3.7

REMOTE
CONTROL

3.7.1

GPI REMOTE
CONTROL
(PARALLEL
REMOTE)

min. 50 ms

+1,5V

+3,5...30V

Pin1...13

Ext. voltage
feed+3,5...30V

Pin14

Contact to
ext. Ground