C8000
8 Channel Mix Matrix with Limiter
C8088
Jünger Audio Studiotechnik GmbH
Justus‐von‐Liebig‐Strasse 7
D ‐12489 Berlin
Germany
phone:
+49‐30‐677721‐0
fax:
+49‐30‐677721‐46
info@junger‐audio.com
www.junger‐audio.com
9/12
Input Selector
selects between two sets of inputs named Main and Alternative
Main Input
you can select a set of 4 busses as the main input of the module
Alternative Input
you can select a set of 4 busses as an alternative input bank
Input Mux Format
here you select if the input audio signals are multiplexed in 2ch or 8ch
mode. If in 8ch mode only the upper bus assignment field will be
available
Output Mux Format
here you select if the output audio signals are multiplexed in 2ch or
8ch mode. If in 8ch mode only the upper bus assignment field will be
available
Enable C8000 Bus Drivers turns off all module bus drivers (tri state mode)
Error Detection
The serial audio data from the frame bus can be monitored for proper
positioning of an Error-Flag. A bad Error-Flag is an indication that
there is disturbance upstream (input signal, input module,
other DSP module).
The Error Detection can be turned Off and On for each input from the
bus. You will see the status of the busses on the left hand side:
“Bus Status”. A grey “LED” shows that the detection is disabled.
While green is OK, red indicates an error condition.
The bus status may be presented to external monitoring systems via
SNMP. The frame controller summarizes such status information and
generates SNMP traps for the frame as an entity or may activate
GPOs (if GPI/O module(s) are installed). The SNMP manager may
afterwards poll the “modulesStatus” for more detailed status
information per input (see SNMP documentation for details).