C8088, C8000 – Junger Audio C8088 - Mix-Matrix & Limiter User Manual
Page 12

digital audio
modular
processing system
C8000
8 Channel Mix Matrix with Limiter
C8088
Jünger Audio Studiotechnik GmbH
Justus‐von‐Liebig‐Strasse 7
D ‐12489 Berlin
Germany
phone:
+49‐30‐677721‐0
fax:
+49‐30‐677721‐46
info@junger‐audio.com
www.junger‐audio.com
12/12
GPI/O
GPIs
are useful if you want to recall settings remotely (e.g. by presets).
The C8k frame can handle 127 different GPIs. You must assign a
unique number to the respective function. Such numbers will be
generated by the brc8x Broadcast Remote Controller or by a GPI/O
interface module. If the C8486 receives such a number by the CAN
bus, it will load the respective preset for example or will turn a bypass
function on.
GPOs (Tallies)
may signal the status of a module by means of relay switches. Those
relays have NO (normally open) as well as NC (normally closed)
contacts. This allows for easy interconnection with more generic
monitoring equipment. If an event occurs the C8446 puts the assigned
number on the CAN bus so a C8817 GPI/O module or the brc8x may
turn on a relay or button LEDs (see C8817 manual for details).