When
programming live
performances as
well as cues that need to
trigger on demand or on a
time line, program no
more than 10 fixtures on
ID addressing per DMX
channel. This is to remain
within a one-second
execution time.
If ID Addressing
is active in a
fixture’s control
panel, unintended results
may occur if DMX channel
6’s value is higher than
“0” when in STd2. Make
sure to disable ID
addressing and to set
DMX channel 6 to “0” if
using STd2.
The master
fixture
becomes
Master when in STAT
mode.
Control Panel Description
Button
Function
Exits from the current menu or function
Enables the currently displayed menu or sets the
currently selected value in to the current function
Navigates upwards through the menu list and
increases the numeric value when in a function
Navigates downwards through the menu list and
decreases the numeric value when in a function
Control Options (SpectraWhite™ Fixtures)
You can set the Ilumipod 42 IP Optic VW start address in the 001~512 DMX range. This
allows for the control of up to 85 fixtures in the 6-channel STd2 personality. In addition, the ID
address system allows you to assign up to 66 fixtures within the same DMX address, thus
multiplying the number of fixtures you can control within a single universe. You can access the
fixture’s ID address system from channel 6 when in the STd2 personality.
Programming
Carry out all the programming procedures indicated below from the control panel. Refer to the
Menu Map in page 15 to learn how the menu options relate to each other.
Use
right and left respectively. Use
options.
DMX Personality
1. Go to MENU > PERS and select any DMX personality.
2. Make sure to rearrange the DMX addresses of all fixtures in the current DMX
universe to avoid address overlapping.
DMX Control Without ID Addressing
1. Go to MENU > RUN and select dMx.
2. Go to MENU > dMx and select a starting DMX address (001~512).
3. Go to MENU > SET > Id and select OFF.
DMX Control With ID Addressing
1. Repeat steps 1 and 2 from DMX Control Without ID Addressing.
2. Go to MENU > SET > Id and select ON.
3. Go to MENU > Id and select an ID address (1~66).
4. When in STd2, channel 6 controls ID addressing.
Master/Slave
On the Master unit:
1. Go to MENU > RUN and select dMx.
2. Go to MENU > STAT and manually set the color values (see Static Colors).
On each of the Slave units:
3. Go to MENU > RUN and select SLAV.