IR/SERIAL
This type of port provides
▪ Output for infra-red emitters (IR Adapter /i, IR Sprayer)
▪ RS-232 serial output (one way). Output signal levels are in the -12 V to +12 V range and baud rate can
be set to the following values: 1 200, 2 400, 4 800, 9 600, 19 200, 38 400, 57 600, 115 200 Bd (bps).
The IR outputs and RS-232 outputs can be combined on independent outputs. For example two outputs can
be used as IR, two outputs can be used as RS-232.
Connector pin out
IR/SERIAL
2-pin 3.5 mm
Pin
Signal
Description
S G
S
Signal
IR/Serial Signal (Output)
G
GND
Ground
Notes
▪ All pins labelled G are connected together.
▪ Up to three original infra-red emitters IR Adapter /i can be connected to each output in parallel.
▪ Up to ten IR Sprayers can be connected to each output in parallel
▪ It is not recommended to connect more infra-red emitters of various manufacturers in parallel because
the output can be either overloaded or damaged.