Cue Site Manager / Programmer’s Manual / Central Station Configuration
© CUE, a.s. All Rights Reserved. | www.cuesystem.com | [email protected]
Step 5 - E-mail Recipients
Click cell in column E-mail Addresses to edit
appropriate e-mail recipient for each type
of request / alert.
More e-mail adresses can be used for each type
of request / alert. These addresses must be separated
by semicolon.
You can test validity of e-mail address and settings by
sending test e-mail message using Test button.
Note
Be sure that SMTP server and other e-mail setings
are correctly set for Central Unit. This settings is
provided in Admin Web (controllers, touch panels) or
in Configuration section (pcCUE).
Step 6 - Send E-mail When Back In Range
Set Yes if you want to send e-mail notofication when
any Parameter value returns to normal range.
Click button to toggle this parameter.
Step 7 - Auto Power Off
This function allows to Power Off all monitored sites
automatically.
Parametrr Auto Power Off Time defines time for Auto
Power Off with period one day (24 hours). Time can be
increased / descreased by arrow buttons or you can
edit it by touching the value cell.
This function can be enabled or disabled by parameter
Enable Auto Power Off. Click button to toggle this
parameter.
Step 8 - Timeout
By this value you can set timeout of IP communications
with monitored site. If Monitored Site doesn’t answer
up to this time, site is displayed as Offline.
Recommended value is between 5 to 20 seconds and it
depends on network infrastructure.
Step 9 - Log Connection
This parameter sets whether changes Online / Offline
are written to log file or not. Click button to toggle
this parameter.