4. Addressing
4.1. Addressing buttons of keypadCUE-8
4.1.1. Addressing rules
The ADDRESS of the buttons and LEDs of keypadCUE-8 can be set in the range 0 to 207. Default
button panel ADDRESS is 1.
The BUTTON_ID transmitted by the panel is the LINK number used in the programming for button
identification. The BUTTON_LED_ID is LED identification for ButtonLed… commands. Both values
depend on the button (LED) position and on a keyboard ADDRESS too. BUTTON_ID is calculated
according to the formulas described below.
BUTTON_ ID
= (32 * ADDRESS) + Button Code
BUTTON_LED_ID
= (32 * ADDRESS) + Button LED Code
The lowest BUTTON_ID is generated by the button in the upper left corner; the highest BUTTON_ID is
generated by the button in the lower right corner - see example in the picture below.
In the table below Button ID range for some addresses is shown.
ADDRESS
BUTTON_ID range = BUTTON_LED_ID range
0 1 8
1 33 40
2 65 72
… … …
207 6625 6632