Installation – CP Electronics MWS5-SA User Manual
Page 4

4
Ø19.5m
Ø3.5m
19mm
Panel mounting using lugs
Flush mounting
Flush fitting behind light fitting diffuser using the flange mount bracket
Use the lugs on rear of detector to
secure into thin sheet metal (1mm
max.).
Glue the flange mount bracket on
to the rear of the diffuser, and
fasten the sensor head in place
using the two longer (19mm high)
bracket clips.
Before gluing, please ensure that
the glue used is compatible with
both the acrylic flange mount
bracket and the diffuser material.
Surface mounting using the base plate
Use the base plate for surface
mounting.
Installation
The product can be mounted into
a flat panel of a luminaire using
the flush mount ring as shown.
0.8mm - 4mm material
Ø43mm (+0, -0.2)
>4mm material
Ø44mm
If flush mounting in a panel that is
greater than 6mm thick, remove bottom
of retention arms with side cutters