FS-97A User’s Manual Watchdog Timer Programming Guide

Watchdog Timer Programming Guide

51

LD8-CRF7- Bit[3..0] : Select IRQ resource for WDT time-out

( Setting of 2 selects SMI )

(3) WDT Programmimg guide

Step 1 . Enter extended function mode as mentioned as above.

Step 2 . Program WDT related CR.

(2-1) CR2B-b[4]P[0] ; Set pin output as WDT function

(2-2) CR07-P08h ; Point to LD8

(2-3) CRF6-Pxyh

; Program WDT time-out period and start

count down . xy = 00 ; No WDT time-out and counting

xy = 01 ; WDT time-out = 30 sec. and starts counting .

............

(2-4) Read CRF7-b4 if needed ; 0 : WDT counting

1 : WDT time-out happened

Step 3. Exit extended function mode as mentioned as above.

Example (ENABLE WDT AND SET WDT time-out = 5 minutes)

Step 1 .

MOV DX,2EH

MOV AL,87H

CLI ; disable interrupt

OUT DX,AL

JMP $+2

OUT DX,AL

STI ; enable interrupt

Step 2 .

MOV DX,2Eh

MOV AL,2BH

OUT DX,AL

MOV DX,2Fh

IN AL,DX ; READ CR2B

AND AL,0EFH

MOV AH,AL

MOV DX,2Eh

MOV AL,2BH

OUT DX,AL

MOV DX,2Fh

MOV AL,AH

OUT DX,AL ; CR2B-b[4]P[0]

MOV DX,2Eh

MOV AL,07H

OUT DX,AL ; point to Logical Device Number Register