Specification, Srp-500 9. specification, Rev. 1.08 – BIXOLON SRP-500 User Manual
Page 27

Rev. 1.08
- 27 -
SRP-500
9. Specification
Printing
Printing method
Serial ink jet matrix method
Printing direction
Bidirectional(logic seeking) with friction feed
Resolution
104 x 96(dpi): Text
208 x 96(dpi): Graphic
Characters per line
Max 42(characters)
Printing speed
6.5 LPS (Lines Per Second) at 40 columns
Printing Width
61.5mm
Line Interval
4.233mm (1/6”)
Character sets
Alphanumeric characters: 95
International characters: 32
Extended graphics : 128 x 12 pages
Character font
14 x 12 / 12 x 12
(24 x 12 ; for Korea, 20 x 24 ; for GB2312)
Paper roll
Type
Normal paper
Size
Width : 76 ± 0.5(mm)
Thickness
0.06 to 0.085(mm)
Maximum outside diameter ø 83mm
Paper core inside diameter ø 10 to 12.5(mm)
Ink cartridge
Model
RIC-500B,R (HP 6602a,r)
Firing frequency
3.0KHz
– low density printing(Text)
1.5KHz
– high density printing(Graphic)
Operating Voltage
19.9 ± 0.5V
Resistance
60 Ω
Operating Temperature
0~45 °C
Date of expiration
2 years after production (at normal temperature)
※ NOTE :
Follow the laws or regulations of your country or community for
disposing of used ink cartridges.
Electrical
characteristics
Supply voltage
24VDC
Current consumption
(at 24V,except for drawer
kick-out driving)
Operating Mean : Approximately 0.5A
Peak : Approximately 1.5A
Standby Mean : Approximately 0.3A
※ NOTE :
Maximum 1A for drawer kick-out driving.
Reliability
Life
Firing frequency
Mechanism : 18,000,000 lines
Auto cutter : 1,500,000 cuts
(End of Life is defined as the point at which the
printer reaches the beginning of the Wear out
Period.)
MTBF
30,000 hours
Environmental
condition
Operating
0 ° to 45 °C
Storage
-20 ° to 60 °C
Shipping
-40 ° to 70 °C
Relative Humidity
Operating : 10 to 80% RH (non-condensing)
Storage : 10 to 90% RH (non-condensing)
Shipping : 5 to 90% RH (non-condensing)
※ NOTE :
Exposure to high or low temperatures for periods of greater than
48 hours will lead to significantly reduced cartridge life.
Printer
Weight
Approx. Wt : 2.7Kg
Shipping. Wt : 3.5Kg
* This equipment is indooruse and all the communication hiring are limited to inside of the building.
* The switch is the disconnecting device. Turn off switch from any hazard.