SRP-500
3-1 Serial Interface (RS232C)
Switch
Function
ON
OFF
Default
1-1
Emulation Selection
Refer to the following table
OFF
1-2
OFF
1-3
Auto cutter
Enable
Disable
ON
1-4
Cartridge
one cartridge
two cartridges
OFF
1-5
Density
*1)
Bold
Normal
OFF
1-6
Special Function
*2)
Enable
Disable
OFF
1-7
Near end sensor
Enable
Disable
ON
1-8
Undefined
OFF
DIP switch Setting 1 Function
Emulation
1-1
1-2
BXL/POS
OFF
OFF
STAR
OFF
ON
BXL/POS-KP
*3)
ON
ON
Emulation Selection
Switch
Function
ON
OFF
Default
2-1
Data receive error
Print “?”
Ignore
OFF
2-2
Reserved
OFF
2-3
Hand Shaking
DTR/DSR
XON/XOFF
OFF
2-4
Word length
7bit
8bit
OFF
2-5
Parity check
Enable
Disable
OFF
2-6
Parity selection
EVEN
ODD
OFF
2-7
Baud rate selection
Refer to the following table
OFF
2-8
OFF
DIP switch Setting 2 Function
Transmission
2-7
2-8
2400 baud
ON
ON
4800 baud
OFF
ON
9600 baud
OFF
OFF
19200 baud
ON
OFF
Baud Rate selection