Srp-150 – BIXOLON SRP-150 User Manual
Page 34
Rev. 1.08
- 34 -
SRP-150
ESC p m t1 t2
[Name]
[Format]
[Range]
[Description]
To generate pulse
ASCII ESC p m t1 t2
Hex 1B 70 m t1 t2
Decimal 27 112 m t1 t2
m = 0, 1, 48, 49
0 ≤t1 ≤255, 0 ≤t2 ≤255
Outputs the pulse specified by t1 and t2 to connector pin m as follows.
m
Connector pin
0, 48
Drawer kick-out connector pin 2
1, 49
Drawer kick-out connector pin 5
ESC t n
[Name] To select the character code table
[Type] ASCII
ESC
t
n
HEX
1B
74
n
DECIMAL 27
116
n
[Ra
nge] 0 ≤ n ≤ 5, n = 11, 255
[Description] n is used to select the character code table as follows.
Chinese version is not supported.
n
Page
0
0: PC437 [U.S.A., standard Europe]
1
1: Katakana
2
2: PC850 [Multilingual]
3
3: PC860 [Portuguese]
4
4: PC863 [Canadian-French]
5
5: PC865 [Nordic]
11
11: PC858 [Euro]
255
Space page
[Default value] n = 0
ESC { n
[Name] To select/cancel the vertical inverted printing mode
[Type] ASCII
ESC
{
n
HEX
1B
7B
n
DECIMAL 27
123
n
[Range]
0 ≤ n ≤ 255
[Description] To select or cancel the vertical inverted printing mode of the characters
- Vertical inverted mode is canceled when LSB is 0.
- Vertical inverted mode is selected when LSB is 1.