Srp-150 – BIXOLON SRP-150 User Manual
Page 33

Rev. 1.08
- 33 -
SRP-150
ESC V n
[Name] To set/clear 90° clockwise rotated character sets
[Type] ASCII
ESC
V
n
HEX
1B
56
n
DECIMAL 27
86
n
[
Range] 0 ≤ n ≤ 1, 48 ≤ n ≤ 49
[Description] To set/clear 90° clockwise rotated character sets depending on the value of
n.
n
Function
0,48
To clear the 90° clockwise rotated character
1,49
To set the 90° clockwise rotated character
ESC \ nL nH
[Name] To set the relative printer position
[Type] ASCII
ESC
\
nL
nH
HEX
1B
5C
nL
nH
DECIMAL 27
92
nL
nH
[Range] 0 ≤ nL ≤ 255
0 ≤ nL ≤ 255
[Description] The beginning point is based on the current position by the horizontal and
vertical motion unit. This command sets the position from the current position.
[(nL + nH X 256) X (horizontal or vertical motion unit)].
ESC a n
[Name] Selective adjustment
[Type] ASCII
ESC
a
n
HEX
1B
61
n
DECIMAL 27
97
n
[Range]
0 ≤ n ≤ 2, 48 ≤ n ≤ 50
[Description] All data for aligning in a line have clear positions.
Adjustment type by the selection of n is as follows.
n
Adjustment
0,48
Left adjustment
1,49
Middle adjustment
2,50
Right adjustment
ESC d n
[Name] To print and n line feed
[Type] ASCII
ESC
D
n
HEX
1B
64
n
DECIMAL 27
100
n
[
Range] 0 ≤ n ≤ 255
[Description] To print the data in the buffer and feed n lines