Fig 4-33 P.T.Z Configuration-Serial Port
Advanced settings include preset setting, cruise setting and track setting.
Enter into MenuSetup P.T.Z Advanced. Refer to Fig 4-34:
Fig 4-34 P.T.Z configuration-advanced
To set up preset:
Step 1: In the Advanced interface, click preset “Setting” button to see a dialog box as Fig
4-35:
Parameter
Meaning
Address
The address of the PTZ device
Baud rate
Baud rate of the PTZ device. Range form: 110, 300, 600, 1200, 2400,
4800, 9600, 19200, 34800, 57600, 115200, 230400, 460800, 921600.
Protocol
Communication protocol of the PTZ device. Range from: NULL,
PELCOP, PELCOD, LILIN, MINKING, NEON, STAR, VIDO,
DSCP, VISCA, SAMSUNG, RM110, HY, N-control.
Simulative
Cruise
If enabled, no matter whether the PTZ device supports cruise or not,
the presets will cruise.