4.INSTALLATION

Connector description

The wiring cable of G65 and G70 provides connectors for power supply, video and I/O
interface

Power
Connector

RS 485
Connector
RJ-11

Video output
BNC

Alarm I/O

RED

: AC 24V

BLACK

: AC 24V

To power supply

YELLOW

: RS485 -

GREEN

: RS 485 +

To keyboard or DVR devices for
telemetric control

RED

: Alarm in 1

PINK

: Alarm in 2

YELLOW

:

GREEN

:

BLACK

: COM

WHITE

: Alarm output - N.O

BLUE

: Alarm output - N.C

AQUA

Alarm in 3
Alarm in 4

:

I/O interface to additional alarm

Alarm output - N.C2

BROWN

: Alarm output - N.O2

GRAY

: Alarm in 7

PURPLE

: Alarm in 6

ORANGE

: Alarm in 5

Inner Conn : Signal +
Outer Conn : Ground
Video Output to monitor or DVR

Using optional accessories

The G65 and G70 speed dome cameras can be connected to various optional
accessories through the standard connector types, which simplifiy the cable handling
and avoids possible mistakes. All accessories are tested for max. compatibility and
best performance.

AU-WP20

Outdoor power adaptor box
AC 230V to AC 24V

AC 24 Power

supply

RS 485

Alarm I/O

AC 230V
Power input

AU-S20

Indoor power adaptor
AC 230V to AC 24V

AU-
S20

AC 230V

Power input

AC 24 Power supply

AU-KB3N

3-Axis keyboard

controller

RS 485

Telemetric control
camera setup

AU-JD2028

21”High Res.
security Monitor.

AU-DVRH-16/400

Professional Real-time
16 Channel DVR

Video signal

RS 485 cable
The telemetric control of the appliance uses Rs485 serial communication with half-
duplex transmission technology.
Depends on the cable typeand baud rate, the transmission distance could vary. The
following table shows max. distances based on cable with 0,56mm (24AWG) twisted
pair:

2400 bps

1100 m

700m

4oom

4800 bps

1700m

9600 bps

19200 bps

Baud Rate

Max. Distance

Due the environmental interferences, such as
eletromagnetic and induction fields, or number of
connected appliance on the RS-485 bus, the
transmission range may be less, e.g with cable thinner
than than 24AWG.