Alarm codes, Connector diagram – Applied Motion STM23R-2ND User Manual
Page 36

Alarm Codes
In the event of a drive fault or alarm, the green LED will flash one or two times, followed by a series of red flashes. The
pattern repeats until the alarm is cleared.
404 Westridge Drive Watsonville, CA 95076
Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544
www.applied-motion.com
Connector Diagram
Code
Error
solid green
no alarm, motor disabled
flashing green no alarm, motor enabled
flashing red configuration or memory error
3 red, 1 green drive overheating
3 red, 2 green internal voltage out of range
4 red, 1 green power supply voltage too high
4 red, 2 green power supply voltage too low
5 red, 1 green over current / short circuit
6 red, 1 green open motor winding
1
2
3
4
5
6
7
8
1
2
3
4
STEP+
STEP-
DIR+
DIR-
EN+
EN-
OUT+
OUT-
V-
V+
S/R
SETUP
This manual is related to the following products: