STM23R Hardware Manual
920-0056C
5/5/2015
Connecting the Digital Output
The STM23R features a digital output labelled “OUT”. This output closes to signal
a fault condition.
This output can be used to drive LEDs, relays and the inputs of other electronic
devices like PLCs. The “+” (collector) and “-” (emitter) terminals of the output transistor are available at the con-
nector. This allows you to configure the output for current sourcing or sinking.
Diagrams of each type of connection follow.
Do not connect the output to more than 30VDC.
The current through the output terminal must not exceed 80 mA.
Sinking Output
STM23R
5-24 VDC
Power Supply
+
–
Load
OUT-
OUT+
!
STM23R
5-24 VDC
Power Supply
+
–
Load
OUT-
OUT+
Sourcing Output
Driving a Relay
STM23R
OUT-
OUT+
1N4935 suppression diode
5-24 VDC
Power Supply
+
–
relay
OUT+
OUT-