Dual, microstepping bipolar recirculating H-bridge, pulse width modulated
switching at 20 kHz. 0.2 - 2.0 amps/phase output current, software pro-
grammable. 50 watts maximum output power. Automatic idle current
reduction. Min. motor inductance 1 mH.
110 or 220 VAC input, switch selectable. 50 - 60 Hz. 75 W max. DC
voltage at nominal line voltage: 28 VDC full load, 40 VDC no load.
8, optically isolated, 2200 ohms input, 12 - 24 VDC.
4, Optically isolated, uncommitted (open collector, open emitter)
darlington photo transistor. 30V, 100 mA max.
Constructed on black anodized aluminum heat transfer plate. Covered by
heavy gauge ventilated steel housing. 1.75 x 4.0 x 6.8 inches overall.
Power on/status LED. See drawing on back cover for more information.
Ambient temperature range: 0 - 50°C.
1A UL rated, fast acting, TR5 style. Available from Digikey (800-DIGIKEY)
as part number WK3048BK.
T
T
T
T
Technical Specifications
echnical Specifications
echnical Specifications
echnical Specifications
echnical Specifications
Amplifier
Power Supply
Digital Inputs
Digital Outputs
Physical
Fuse
Mating Connectors and Accessories
Mating Connectors
Motor: Mating connector included. Phoenix P/N 1753075.
AC Power: Phoenix P/N 1832536. Included with drive.
IN/OUT: DB-25 female. Mating connector included, NORCOMP P/N 171-025-202-001.
Shell Kit: AMP P/N748678-3 (included).
Accessories
Breakout Box for IN/OUT Connector: BOB-2, includes cable
Screw Terminal Connectors that mate directly to the IN/OUT connector on the front panel of
the drive:
This connector is not available from Applied
Motion. You m
Mating Cable for IN/OUT connector with “flying leads”
Black Box P/N: BC00702.
This cable is not available from Applied Motion. You must
Useful for custom wired applications. This shielded cable has
a DB-25 connector on each end. If you cut one end off it will provide a 6 foot “DB-25 to
flying lead cable” for the IN/OUT connector. It’ll be easier to wire if y
Surge Protector with Line Filter: