Programmable Outputs
The Si2035 has four programmable outputs.
These optically isolated, photodarlington outputs can be
used to drive LEDs, relays and the inputs of other elec-
tronic devices like PLCs and counters. On the IN/OUT
connector outputs, both the “+” (collector) and “-” (emitter)
terminals of each transistor are available on the connector
pins. This allows you to configure each output for current
sourcing or sinking.
Diagrams of each type of connection follow.
Do not connect the outputs to more than 30VDC.
The current through each output terminal must not exceed 100 mA.
inside Si2035
OUT1+
OUT1-
OUT2+
OUT2-
OUT3+
OUT3-
OUT4+
OUT4-
18
19
20
21
22
23
24
25
PLC
Si2035
12-24 VDC
Power Supply
+
–
OUT-
OUT+
IN
COM
Si2035
OUT-
OUT+
5-24 VDC
Power Supply
+
–
Load
Si2035
OUT-
OUT+
1N4935 suppression diode
5-24 VDC
Power Supply
+
–
relay