Performance, Reading conditions, 2 performance – Datalogic Scanning DS6300 User Manual
Page 80: 1 reading conditions

DS6300
4
The decoder will be able to read the label with a tilt angle between
+
α max and - α max as shown in the following figure:
Conveyor
Laser Beam
No Read
No Read
-
α
+
α
0
°
OK
OK
OK
OK
OK
No Read
Figure 77 – Reading Zones with
α Max
4.2 PERFORMANCE
The scan rate is 800 scans/sec.
Refer to the diagrams in par. 4.3 for further details on the reading features. These diagrams
are taken on various resolution sample codes at a 25
°C ambient temperature depending on
the conditions listed under each diagram.
4.2.1 Reading
Conditions
• ANSI Grade B minimum
• 800 scans/sec
The following tables describe the requirements for standard applications.
Minimum Code Height for ACR Reading (mm)
45°
30°
Conveyor
Speed
(m/s)
0.5 1 1.5
2 2.5
3 0.5
1 1.5 2 2.5
3
0.25
10 12 14 16 18 20
7 9 10 12 13 15
0.30
12 14 15 17 19 21
8 9 11 12 14 15
0.33
13 14 16 18 20 22
8 10 11 13 14 16
0.38
14 16 18 19 21 23
9 11 12 14 15 17
0.50
18 19 21 23 25 26
11 12 14 15 17 18
0.72
24 25 27 28 30 32
15 16 17 19 20 22
2/5 Interleaved
Code Resolution
(mm)
1.00
33 34 35 36 38 40
20 21 22 23 25 26
Ratio 3:1
Table 1
66