MAN#650231:A

Pulls up all values

 on speed and speed pulses in odometer

Press Right switch to finish cal and save value

ADJUST

Adjust speed cal while driving

ADJUST

Each press of left switch toggles direction of adjustment, right switch to save and exit

SRV MI (SRV KM)

Sets value of service odometer set when service odometer is reset

OFF ( OFF) Turns off the count down service odometer (default)

500 ( 800) Sets service to 500 mi or 800 km when resetting service odometer.

….

Service point can be set in 500 mi (800km) increments.

7500 (12000) Sets service to 7500 mi or 12000 km when resetting service odometer.

MAIN

Returns to info menu



TACH

Tachometer gauge menu

ENGINE

Sets number of cylinders from 1-15 (default 12 for use on alternator output)

WARN

Sets RPM warning point (default 5500 RPM)

W 2250

Minimum warning point of 2250 RPM

….

Warning point can be set in 250 RPM increments

W 9750

Maximum warning point of 9750 RPM

SRV HR

Sets service hour value used when resetting count down service hour meter

OFF

Service hour meter disabled (default)

10

Minimum service hour set point

Service hour reset point can be set in 10 hr increments

310

Maximum service hour set point

MAIN

Returns to info menu


GAUGES

Gauge option menu

VLT HI

Set high voltage warning point (default 15.4V)

VLT LO

Set low voltage warning point (default 11.1 V)

FL SND

Set fuel sender used

NONE

No fuel sender used, fuel area will be blanked out (default)

STOCK

Uses stock fuel sender for Rhino

DAKDIG

Uses Dakota Digital sender to be installed in tank

CUSTOM

Uses custom sender, user must calibrate for the sender curve

CAL Y (CAL N) Select CAL Y to calibrate sender

EMPTY

Start with empty tank, or fuel sender in empty position

ADD 33

Fill fuel to 1/3 tank, press right switch to save point

ADD 66

Fill fuel to 2/3 tank, press right switch to save point

ADD 99

Fill fuel to full tank, press right switch to save point

DONE

Custom fuel calibration is complete, press right switch to go back to menu

OIL LO

Set low oil pressure warning point (default 9 PSI)

WTR HI

Set high water temp warning point and set temperature unit (default 230F)

DEG F (DEG C)

Select temp unit, press left switch to change, right switch to save

WTR HI

Select high warning, left switch to change, right switch to save

MAIN

Returns to info menu


OPTION

Option menu

DIM LV

Adjust dimming point on gauge

OFF

Dimming function is off

LVL 1

Gauge will dim when light on gauge face is very low (default)

7 selectable dimming levels

LVL 7

Gauge will dim early when more light is on gauge face

DM OUT

Enables/disables dim output for other gauges

ON

Dim output will be high when gauge is dimming

OFF

Dim output will be disabled (default)

WN OUT

Selects which gauges provide a warn out signal on warn out wire (default all on)

WN OUT

Gauges that provide signal out are lit up, left switch to change, right switch to save

NO WRN

Warn output wire is disabled