Installation, Introduction – Nexen TA100 964400 User Manual
Page 5

1
FORM NO. L-20292-C-0700
INSTALLATION
NOTE
The TA100 and TA110 Tension Amplifiers are electronic components and should be mounted in a dry, dust free,
shock, and vibration free area with an ambient temperature greater than 32° F [0° C] but less than 122° F [50° C].
TA100/TA100A GENERAL DIMENSIONS
FIGURE 1
INTRODUCTION
The TA100 and TA110 Tension Amplifiers interface with load
cells to measure tension in a continuous web strip or strand
of material during converting or printing. This material can be
paper, film, foil, rubber, wire, metal strip, non-woven, or tex-
tiles used in any continuous process.
Used with any Nexen MB, CFL or SW type sensor, Nexen
Tension Amplifiers provide an excitation signal to the sensor
NOTE
The TA100A and TA110A Tension Amplifiers are 24 Volt DC versions of the TA100 and TA110 Tension Amplifiers.
When TA100 is referenced in this manual, the information relates to both the TA100 and TA100A Tension Amplifiers.
When the TA110 is referenced in this manual, the information relates to both the TA110 and TA110A Tension Amplifiers.
and then separately amplify the return signals from each
sensor. These signals from both sensors are then added to
provide the 0-10VDC or 4-20mA proportional tension output.
The TA100 is complete with a NEMA-12 enclosure for adding
to an existing tension control drive or other retrofit installation.
The TA110 is chassis-mounted for OEM installations in
cabinets or enclosures.
The TA100A and TA110A Tension Amplifiers are 24 Volt DC
versions of the TA100 and TA110 Tension Amplifiers.
WARNING
The TA100A and TA110A
are powered by 24VDC and
will be damaged by
110VAC.