Installation (continued), Lubrication – Nexen DPC-13T 962200 User Manual
Page 8

8
FORM NO. L-20093-L-1209
SHEAVE CLUTCH
Refer to Figure 5.
NOTE: The Sheave Clutch is a combination of the Element
Clutch, Pilot Assembly, and Sheave.
1. Proceed with Steps 1 through 5 for the Pilot Clutch
installation.
2. Slide the Sheave (Item 32) onto the Pilot Assembly.
3. Align the sheave mounting holes with the tapped holes
in the Pilot Housing (item 23).
4. Using Cap Screws (Item 33), and Lockwashers (Item
34), secure the Sheave onto the Pilot Assembly.
5. Tighten the Cap Screws (Item 33) to the recommended
torque (See Table 5).
6. Proceed with Steps 6 through 12, for the Pilot Clutch
installation.
FIGURE 5
33
34
32
23
TABLE 5
N
O
I
T
P
I
R
C
S
E
D
T
3
1
-
C
P
D
T
5
1
-
C
P
D
)
1
2
m
e
tI
(
w
e
r
c
S
p
a
C
.
S
B
L
.
T
F
9
1
1
.
S
B
L
.
T
F
9
1
1
)
8
2
m
e
tI
(
w
e
r
c
S
p
a
C
.
S
B
L
.
T
F
8
4
.
S
B
L
.
T
F
8
4
)
3
3
m
e
tI
(
w
e
r
c
S
p
a
C
.
S
B
L
.
T
F
9
1
1
.
S
B
L
.
T
F
9
1
1
0
2
m
e
tI
(
t
u
N
k
c
o
L
.
S
B
L
.
T
F
0
7
.
S
B
L
.
T
F
0
7
s
tl
o
B
P
U
-l
l
u
P
.
S
B
L
.
T
F
5
7
.
S
B
L
.
T
F
2
1
1
INSTALLATION (continued)
NOTE
Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance and life.
All seals in Nexen pneumatically operated devices are lubricated for life, and do not require additional lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air, forcing
an oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air mist lubrication
system is used, it is continually used over the life of the product as the oil mist may wash free the factory
installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.
LUBRICATOR DRIP RATE SETTINGS
1. Close and disconnect the air line from the unit.
2. Turn the Lubricator Adjustment Knob counterclockwise
three complete turns.
3. Open the air line.
LUBRICATION
CAUTION
These settings are for Nexen supplied
lubricators. If you are not using a Nexen
lubricator, calibration must follow the
manufacturer's suggested procedure.
4. Close the air line to the unit when a drop of oil forms
in the Lubricator Sight Gage.
5. Connect the air line to the unit.
6. Turn the Lubricator Adjustment Knob clockwise until
closed.
7. Turn the Lubricator Adjustment Knob counterclockwise
one-third turn.
8. Open the air line to the unit.