Capacitance and diode test specifications – Fluke 289 User Manual
Page 83

True-rms Digital Multimeters
Detailed Specifications
73
Capacitance and Diode Test Specifications
Function Range Resolution
Accuracy
1 nF
[1]
0.001 nF
1 % + 5
10 nF
[1]
0.01 nF
1 % + 5
100 nF
[1]
0.1 nF
1 % + 5
1
μ
F 0.001
μ
F
1 % + 5
10
μ
F 0.01
μ
F
1 % + 5
100
μ
F
0.1
μ
F
1 % + 5
1000
μ
F 1
μ
F
1 % + 5
10 mF
0.01 mF
1 % + 5
Capacitance
100 mF
0.1 mF
2 % + 20
Diode Test
3.1 V
0.0001 V
1 % + 20
[1]
With a film capacitor or better, using relative mode (REL
Δ
) to zero residual.
This manual is related to the following products: