Resistance specifications, Temperature specifications – Fluke 289 User Manual
Page 82

287/289
Users Manual
72
Resistance Specifications
Function Range Resolution
Accuracy
50
Ω
[1][3]
0.001
Ω
0.15 % + 20
500
Ω
[1]
0.01
Ω
0.05 % + 10
5 k
Ω
[1]
0.0001
k
Ω
0.05 % + 2
50 k
Ω
[1]
0.001
k
Ω
0.05 % + 2
500 k
Ω
0.01
k
Ω
0.05 % + 2
5 M
Ω
0.0001
M
Ω
0.15 % + 4
30 M
Ω
0.001
M
Ω
1.5 % + 4
50 M
Ω
0.01
M
Ω
1.5 % + 4
50 M
Ω
up to 100 M
Ω
0.1
M
Ω
3.0 % + 2
Resistance
100 M
Ω
up to 500 M
Ω
0.1
M
Ω
8 % + 2
Conductance 50
nS
[2]
0.01 nS
1 % + 10
[1]
When using the relative mode (REL Q) to compensate for offsets.
[2]
Add 20 counts above 33 nS in 50 nS range.
[3] 289
only.
Temperature Specifications
Temperature Resolution Accuracy
[1,2]
-200
°
C to +1350
°
C 0.1
°
C
1 % + 10
-328
°
F to +2462
°
F 0.1
°
F
1 % + 18
[1]
Does not include error of the thermocouple probe.
[2]
Accuracy specification assumes ambient temperature stable to ±1
°
C. For ambient temperature changes of ±5
°
C, rated accuracy applies after 2 hours.