background image

1645-00 X-16 CORDLESS TELEPHONE MODULE

9

Programming the Cordless Telephone Module

Programming Code Table

Parameter

Access Codes

Description

Registering the
Cordless
Telephone module

## + Ext + ##

Ext = 301 – 399 – Must be
an unused Extension
Number

Page 10

Enable/Disable
Ringing

##+5+L+R+##

L=Line number between 1
– 6 R=1 for on and 0 for off

Page 10

Call Forward –
Enable/Disable

##+801+##+T

T= Forwarding Type
0=Off, 1=Voicemail,
2=External, 3=Trk2Trk

Page 11

Call Forward –
Wait Time

##+802+##+tt

tt= Time before Forwarding
Valid entries are 00 – 25.

Page 12

Call Forward –
External Number

##+803+##+Tn+#

Tn=Telephone Number to
Dial, such as a cellular
telephone

Page 13

Voicemail Change
Password

##+800+##+ddd

ddd=New three digit
passcode

Page 14

Factory Default

# # + 000 + # #

Initializes the unit to factory
default

Page 14