Horizontal dimensional data cont, Horizontal disconnect, Envision – WaterFurnace Envision2 User Manual
Page 9: Compact installation manual
9
ENVISION
2
COMPACT INSTALLATION MANUAL
Horizontal Dimensional Data cont.
2.1 in.
[5.3 cm]
KK
Disconnect Located
on this Side for a
Left Return
Disconnect
Location
Power Supply
Horizontal Shown in
Right Return Configuration
Horizontal
Models
Overall Cabinet
Water Connections
Electrical Knockouts
1
2
3
J
K
A
B
C
D
E
H
Loop
1/2 in. cond
1 in. cond
Width
Depth
Height*
In
Out
Condensate
Water FPT
Low Voltage Power Supply
009-012
in.
22.5
35.0
17.2
1.8
6.8
0.8
1/2 in.
7.1
7.1
cm.
57.2
88.9
43.7
4.6
17.3
2.0
12.7 mm
18.0
18.0
015-018
in.
22.5
42.0
19.2
1.8
6.8
0.8
3/4 in.
9.1
7.1
cm.
57.2
106.7
48.8
4.6
17.3
2.0
19.05 mm
23.1
18.0
024-030
in.
22.5
45.0
19.2
1.8
6.8
0.8
3/4 in.
9.2
7.1
cm.
57.2
114.3
48.8
4.6
17.3
2.0
19.05 mm
23.4
18.0
036-038
in.
25.5
48.0
21.2
1.8
6.8
0.8
1 in.
9.2
9.1
cm.
64.8
121.9
53.8
4.6
17.3
2.0
25.4 mm
23.4
23.1
042-049
in.
25.5
53.0
21.2
1.8
6.8
0.8
1 in.
9.2
9.1
cm.
64.8
134.6
53.8
4.6
17.3
2.0
25.4 mm
23.4
23.1
060-064
in.
25.5
61.0
21.2
1.8
6.8
0.8
1 in.
9.2
9.1
cm.
64.8
154.9
53.8
4.6
17.3
2.0
25.4 mm
23.4
23.1
070-072
in.
25.5
68.0
21.2
1.8
6.8
0.8
1 in.
9.2
9.1
cm.
64.8
172.7
53.8
4.6
17.3
2.0
25.4 mm
23.4
23.1
3/16/12
Horizontal
Models
Discharge Connection
duct fl ange installed (±0.10 in.)
Return Connection
using deluxe fi lter rack option (±0.10 in.)
PVC Size
L
M
N
P
Q
R
S
T
X
Supply Width Supply Depth
Return Depth Return Height
009-012
in.
5.9
7.2
9.5
6.0
16.4
14.5
2.0
1.4
3/4”
cm.
15.0
18.3
24.1
15.2
41.7
36.8
5.1
3.6
1.9
015-018
in.
6.7
10.5
9.4
4.9
27.4
16.6
2.0
1.4
3/4”
cm.
17.0
26.7
23.9
12.4
69.6
42.2
5.1
3.6
1.9
024-030
in.
6.7
10.5
9.4
4.9
30.4
16.6
2.0
1.5
3/4”
cm.
17.0
26.7
23.9
12.4
77.2
42.2
5.1
3.8
1.9
036-038
in.
4.9
13.6
13.2
4.6
35.4
18.6
2.3
1.4
3/4”
cm.
12.4
34.5
33.5
11.7
89.9
47.2
5.8
3.6
1.9
042-049
in.
4.9
13.6
13.2
4.6
40.4
18.6
2.3
1.4
3/4”
cm.
12.4
34.5
33.5
11.7
102.6
47.2
5.8
3.6
1.9
060-064
in.
4.9
13.6
13.2
4.6
45.4
18.6
2.3
1.4
3/4”
cm.
12.4
34.5
33.5
11.7
115.3
47.2
5.8
3.6
1.9
070-072
in.
4.9
13.6
13.2
4.6
45.4
18.6
2.3
1.4
3/4”
cm.
12.4
34.5
33.5
11.7
115.3
47.2
5.8
3.6
1.9
Horizontal units shipped with standard 2 in. (fi eld adjustable to 1 in.) open application fi lter rack extending 2.2 in. from unit and is
not suitable for duct connection, for ductable return connection applications, order the deluxe 2 in. (fi eld adjustable to 1 in.) fi lter
rail/fi lter rack which extends 3.25 in. from the unit and is suitable for duct connections.
3/16/12
Horizontal Models
KK
009-012
8.2 [20.8]
015-018
9.2 [23.4]
024-030
9.2 [23.4]
036-038
11.2 [28.4]
042-049
10.2 [25.9]
060-064
11.2 [28.4]
070-072
10.2 [25.9]
Dimensions in inches [cm]
3/16/12
Horizontal Disconnect
When using disconnect, do not use dimension K from the
standard horizontal dimensional data. Use dimension KK from
the horizontal disconnect dimensional data.