Vertical Dimensional Data cont.

LL

1.8 in.

[4.6 cm]

Alternative
Power
Location

Disconnect Located on this
Side for a Right Return

Disconnect
Location

Power

Supply

Vertical Shown in

Left Return Configuration

Vertical

Models

Overall Cabinet

Water Connections

Electrical Knockouts

6

7

8

1

2

3

4

5

J

K

L

A

B

C

D

E

F

G

H

Loop

Knockout

1/2 in.

cond

1/2 in.

cond

1 in. cond

Width

Depth

Height*

In

Out

HWG In HWG Out

Cond-

ensate

Water

FPT

HWG

Provisions

Low

Voltage

Low

Voltage

Power

Supply

009-012

in.

22.5

22.2

30.2

2.6

7.6

N/A

N/A

10.8

1/2 in.

N/A

9.4

5.4

7.4

cm.

57.2

56.4

76.7

6.6

19.3

N/A

N/A

27.4

12.7 mm

N/A

23.9

13.7

18.8

015-018

in.

22.5

26.2

40.2

2.6

7.6

1.4

4.4

10.8

3/4 in.

0.875

10.1

6.1

8.1

cm.

57.2

66.5

102.1

6.6

19.3

3.6

11.2

27.4

19.1 mm

22.2 mm

25.7

15.5

20.6

024-030

in.

22.5

26.2

44.2

2.6

7.6

1.4

4.4

10.8

3/4 in.

0.875

10.1

6.1

8.1

cm.

57.2

66.5

112.3

6.6

19.3

3.6

11.2

27.4

19.1 mm

22.2 mm

25.7

15.5

20.6

036-038

in.

25.5

31.2

44.2

2.6

7.6

1.4

4.4

10.8

1 in.

0.875

10.1

6.1

8.1

cm.

64.8

79.2

112.3

6.6

19.3

3.6

11.2

27.4

25.4 mm 22.2 mm

25.7

15.5

20.6

042-049

in.

25.5

31.2

48.2

2.6

7.6

1.4

4.4

10.8

1 in.

0.875

10.1

6.1

8.1

cm.

64.8

79.2

122.4

6.6

19.3

3.6

11.2

27.4

25.4 mm 22.2 mm

25.7

15.5

20.6

060-072

in.

25.5

31.2

52.2

2.6

7.6

1.4

4.4

10.8

1 in.

0.875

10.1

6.1

8.1

cm.

64.8

79.2

132.6

6.6

19.3

3.6

11.2

27.4

25.4 mm 22.2 mm

25.7

15.5

20.6

3/16/12

Vertical

Models

Discharge Connection

duct fl ange installed (±0.10 in)

**Return Connection

using deluxe fi lter rack (±0.10 in)

M

N

P

Q

R

S

T

U

V

W

Filter Rack

Width

Supply

Width

Supply

Depth

Return

Depth

Return
Height

009-012

in.

2.2

10.0

10.0

6.1

5.3

9.8

2.0

18.1

14.0

2.0

cm.

5.6

25.4

25.4

15.5

13.5

24.9

5.1

46.0

35.6

5.1

015-018

in.

2.2

14.0

14.0

6.1

4.5

7.7

2.0

22.1

22.0

1.9

cm.

5.6

35.6

35.6

15.5

11.4

19.6

5.1

56.1

55.9

4.8

024-030

in.

2.2

14.0

14.0

6.1

4.5

7.7

2.0

22.1

26.1

1.8

cm.

5.6

35.6

35.6

15.5

11.4

19.6

5.1

56.1

66.3

4.6

036-038

in.

2.2

18.0

18.0

6.6

4.6

6.3

1.6

28.1

26.1

2.0

cm.

5.6

45.7

45.7

16.8

11.7

16.0

4.1

71.4

66.3

5.1

042-049

in.

2.2

18.0

18.0

6.6

4.6

6.3

1.6

28.1

30.0

2.0

cm.

5.6

45.7

45.7

16.8

11.7

16.0

4.1

71.4

76.2

5.1

060-072

in.

2.2

18.0

18.0

6.6

5.0

6.4

1.6

28.1

34.0

2.0

cm.

5.6

45.7

45.7

16.8

12.7

16.3

4.1

71.4

86.4

5.1

Condensate is 3/4 in. PVC female glue socket and is switchable from side to front.
*Discharge fl ange is fi eld installed and extends 1 in. (25.4 mm) from top of cabinet.
**Vertical units shipped with standard 2 in. (fi eld adjustable to 1 in.) open application fi lter rack extending 2.2 in. from
unit and is not suitable for duct connection, for ductable return connection applications, order the deluxe 2 in. (fi eld
adjustable to 1 in.) duct collar/fi lter rack which extends 3.25 in. from the unit and is suitable for duct connections.

3/16/12

Vertical Models

LL

009-012

17.8 [45.2]

015-018

14.3 [36.3]

024-030

15.3 [38.9]

036-038

14.3 [36.3]

042-049

14.3 [36.3]

060-064

14.3 [36.3]

070-072

External

Dimensions in inches [cm]

3/16/12

Vertical Disconnect

When using disconnect, do not use dimension L from
the standard vertical dimensional data. Use dimension
LL from the vertical disconnect dimensional data.