6 CHANNEL 3 INSTANT/LATCHED/LATCHED RESET WITH IGNITION/30-SECOND TIMED/60-SECOND TIMED/90-

SECOND TIMED: Channel 3 can be programmed for these output configurations. The unit is set to the default

instant output. To change the configuration, use

to toggle to the different settings.

7 DISARM PULSE COUNT 1 to 5 PULSES: This feature allows you to program the number of pulses used to man-

ually disarm the system using the Valet button. The factory default setting is one pulse. The unit can be set for

2 to 5 pulses using the two-chirp setting to select the pulse count.

multi-level security arming

Multi-Level Security Arming is a feature that allows you to select which of the system's inputs or sensors will be

active and which will be bypassed at the time that the system is armed. (See Table of Zones section in this guide.)

This feature is available only when using a remote that has been programmed with separate arm and disarm

buttons. Pressing the arm button again within five seconds of arming the system will activate the Multi-Level

Security Arming feature. Each time the arm button is pressed again, a different security level is selected. The

different security levels can be selected as follows:

■ Pressing

one time: The siren chirps once. The system is armed.

■ Pressing

a second time within five seconds: The siren chirps twice followed by a long chirp. Zone Two

is now bypassed.

■ Pressing

a third time within five seconds: The siren chirps three times followed by a long chirp. Zone

Four is now bypassed.

■ Pressing

a fourth time within five seconds: The siren chirps four times followed by a long chirp. Zones

Two and Four are now bypassed.

■ Pressing

a fifth time within five seconds: The siren chirps five times followed by a long chirp. All input

zones, except the ignition, are now bypassed.

NOTE: For watercraft, we recommend turning off the shock sensor (Zone Two) whenever the craft
is in the water to avoid false triggers.