Taser X26 User Manual
Page 7

TASER® CDPM Operating Manual •
MMU0014 Rev: B
7
3. Remove the DPM from the X26 device (Figure 5).
4. Insert the green CCDPM into the X26 device. Verify that the DPM release
button (Figure 5) pops out from the recessed position with an audible click
(failure to do so could result in a damaged X26 device or a loss of power
during configuration).
5. If your X26 device has version 21 software or greater, a “P” is displayed on the
device’s Central Information Display (CID) for about six seconds, indicating that
the configuration code is being programmed into the device (Figure 6).
If your X26 device is programmed with version 20 or earlier, this process will
take about 14 seconds. When programming is complete, a two digit CCDPM
version level is displayed, and then the CID display will turn off.
Note: If the CID displays a “P”, then the error code “EO”, the X26 device is a citizen
model (X26C). In this instance, insert a standard DPM programmed with version 22
or higher into the device in order to recover it.
Figure 5
Figure 6