beautypg.com

Infostation environmental information and set-up, Status – StorCase Technology 14-Bay 4U SCSI Ultra320 User Manual

Page 22

background image

InfoStation User Interface

13

InfoStation 14-Bay U320 User's Guide - Rev. A00

StorCase Technology, Inc.

InfoStation Environmental Information and Set-Up

Status

The following steps show how to access the various InfoStation status information.

NOTE:

Press CANCEL at anytime to exit the menu system and return to the Default

Display. The menu system will automatically cancel after 15 seconds of

User inactivity.

1.

Press ENTER at the Default Display so that

display = Status.

2.

Press ENTER so that display = Avg:xxC.

This display shows the average temperature in-

side the InfoStation chassis.

3.

Press DOWN until display = DUALxxxx.

This display shows the type of RAID Controller

Module installed (if installed).

4.

Press DOWN until display = Ch3:xxx.

This display shows the SCSI mode of Channel 3

(xxx represents either LVD or SE).

Press DOWN to scroll through Channels 2-0.

5.

Press DOWN until display = NumCha:x.

This display shows the number of channels

configured for the InfoStation chassis.

6.

Press DOWN until display = Fans:x.

This display shows the number of blowers

configured for the InfoStation chassis.

7.

Press DOWN until display = 12.xxV.

This display shows the InfoStation system 12V

reading.

8.

Press DOWN until display = 5.xxV.

This display shows the InfoStation system 5V

reading.

9.

Press DOWN so that display = Ext:xxC.

This display shows the temperature outside the

InfoStation chassis.

ENTER

S t a t u s

T E M P : x x C

A v g : x x C

C h 3 : x x x

ENTER

DOWN

DOWN

DOWN

DOWN

UP/DOWN

DOWN

C h 0 : x x x

DOWN

5 . x x V

1 2 . x x V

D U A L x x x x

E x t : x x C

F a n s : x

N u m C h a : x

DOWN