Adjusting the Spin Down/Up Timer
The timer for device spin down is controlled by a small selector, located in a cutout on the side
of the DE150i-SWC receiving frame as shown in Figure 10. When the key is turned to the OFF
position, and when the timer receives a No SCSI Activity signal from the Isola-tor Board, it waits
the specified delay time before displaying a u on the front panel of the receiving frame. The
amount of time required for a disk drive to spin down is approxi-mately 15 seconds or more.
This number can vary depending on the type of SCSI device and manufacturer (e.g. a Seagate
Barracuda may require 45 seconds). The factory configuration is set for 20 seconds. A
different delay time may be selected with the provided alignment tool. Refer to the SCSI device
manufacturers manual for more information on required device spin down time.