Installing the receiving frame – StorCase Technology DE110 User Manual
Page 17
10
Installation
StorCase Technology, Inc.
Ultra320 DE110 User's Guide - Rev. A03
Figure 8A: Receiving Frame Mounting Holes
Mounting
Holes
(Right)
Mounting
Holes
(Left)
0837
Mounting
Holes
(Bottom)
Front of Unit
Installing the Receiving Frame
NOTE:
Use a #2 Phillips screwdriver for this procedure.
The drive should be installed into the carrier before installing the receiving frame into the
mounting bay of a computer or expansion chassis.
1.
Turn OFF power to the computer.
2.
Open the computer system according to the manufacturer’s instructions. If
necessary, temporarily remove any expansion boards that may make installation
difficult.
3.
With the drive carrier locked in place inside the receiving frame, install the Ultra320
DE110 into the 5.25” drive opening in the computer or expansion chassis. Use the
appropriate guides to position the Data Express, and fasten it into place with the four
(4) #6-32 Phillips screws provided. Figure 8A illustrates the location of the mounting
holes. Mounting holes are provided on each side and the bottom of the receiving
frame to accommodate a variety of mounting configurations. Use the mounting holes
which best suit the computer or expansion chassis configuration. Note that bottom
mounting holes require self-tapping screws (not provided).
4.
Adjust the front of the receiving frame so the carrier slides freely in and out on the
receiving frame guides. The position of adjoining peripheral units may require
adjustment.