页 11, Specification error message, Error message specification – SkyRC T6755 Charger User Manual
Page 11
SPECIFICATION
ERROR MESSAGE
AC Input
DC Input
Charge circuit power
Charge current range
Discharge current range
Current drain for balancing port
NiCd/NiMH battery cell count
LiPo/LiFe/Lilon cell count
Pb battery voltage
Net weight
Dimension
100-240V
11-18Volt
55W
0.1-7.0A
5W
0.1-2.0A
200mA/cell
1-15Cells
1-6Cells
2-20V
540g
140x165x60mm
Discharge current power
THE SET CONTAINS
1. SKYRC T6755 Charger
2. Multiple Balancing Board
3. 18AWG Wire Charging Cable
4. Power Cord
T6755
T6755
19
18
1
2
3
4
"
INT. TEMP TOO HIGH"
"EXT. TEMP TOO HIGH"
"DC IN TOO LOW"
"DC IN TOO HIGH"
"OVER TIME LIMIT"
"OVER CAPACITY LIMIT"
"REVERSE POLARITY"
"CONNECTION BREAK"
"CELL NUMBER ERROR"
"BALANCE CONNECTER ERROR"
"NO BATTERY"
"CONNECTION ERROR"
"BATTERY WAS FULL"
It incorporates a variety of functions for the systems to verify processes and the state of the
electronics. In case of an error the screen will display the cause of error and emit an audible
sound.
Incorrect polarity connected.
The battery is interrupted.
The Battery connection is wrong.
The cell number is wrong.
The internal temperature of the unit goes too high.
Input voltage less than 11V.
Input voltage higher than 18V.
The battery voltage is higher than the maximum
voltage which the user sets when charging in
balance mode.
The external temperature of the unit goes too high.
The battery capacity is more than the maximum
capacity which the user sets.
The charging time is longer than the maximum
charging time which the user sets.
The balance connect is wrong.
There is no battery connecting to the charger.
ERROR
MESSAGE
EXPLANATION
ERROR MESSAGE
SPECIFICATION