页 10, Setting – SkyRC T6755 Charger User Manual
Page 10
SETTING
You could do SYSTEM SETTING, SAFETY PROTECTION and CHARGER PARAMETER
settings when you enter to Setting program.
Please touch “ ” and “ ” to go to previous or next setting phase and touch “NEXT” to enter
to current setting program.
ITEM
KEY BEEP
BUZZER
LCD LIGHT
THEME
SELECTION
ON/OFF
ON/OFF
1-5
BLUE, RED,
YELLOW, GREEN
DESCRIPTION
The beep sounds at every time touching the screen to confirm
your action. The beep or melody sounded at various times
during operation to alert different mode changes.
The brightness of the LCD can be adjusted basing on
personal preference.
Different color theme can be selected basing on personal
preference.
1. SYSTEM SETTING
▲
▲
ENTER
HOME
LCD LIGHT
5
SYSTEM
SETTING
KEY BEEP
ON
ON
BUZZER
THEME
语 言
中 文
RESTORE
ENTER
NEXT
SETTING
SYSTEM
SETTING
Please touch the referred setting(selections) to change it.
When touching “RESTORE” the charger will restore factory default settings.
2. SAFETY PROTECTION
ITEM
SELECTION
DESCRIPTION
CAPACITY
CUT OFF
SAFETY
TIME
TEMP
CUT OFF
This program sets the maximum charge capacity that will be
supplied to the battery during charge. If the delta peak voltage
is not detected nor the safety timer expired by any reason, this
feature will automatically stop the process at the selected
capacity value.
When you start a charge process, the integral safety timer
automatically starts running at the same time. This is
programmed to prevent overcharge the battery if it proves to
be faulty, or if the termination circuit cannot detect the battery
full. The value for the safety timer should be generous enough
to allow a full charge of the battery.
The battery's internal chemical reaction will cause the
temperature of the battery to rise. If the temperature limit is
reached, the process will be terminated.
ENTER
CAPACITY
CUT OFF
5000 mAh
120 Min
TEMP
CUT OFF
.
45 C/113 F
NEXT
HOME
SAFETY
PROTECTION
SAFETY
TIME OFF
Please touch and screen to make the functions ON or OFF. And touch “ ”
and “ ” to get the proper parameter.
NOTE: The TEMP CUT OFF function can not be OFF.
CAPACITY
CUT OFF
SAFETY
TIME OFF
▲
▲
3. CHARGER PARAMETER
ITEM
SELECTION
DESCRIPTION
This is the voltage level that T6755 will stop charging the
battery.
Intended ONLY for expert users and racers, completely at
their own risk, which allows LIPO and LIFE packs to be
charged in excess of recommended cell terminal voltages.
This is the voltage level that T6755 will stop discharging the
battery, and is shown as volts PER CELL in the pack (not total
pack voltage).
The battery is on the cyclic process of charge and discharge
can often become warm after charge or discharge period. The
program can insert a time delay to occur after each charge
and discharge process to allow the battery adequate time to
cool down before being subjected to the next process.
TERMINAL
VOLTAGE
CONTROL
(TVC)*
END VOLT
DISCHARGE
REST TIME
END VOLT
CHARGE
.
REST
TIME
4.20V
60 Min
ENTER
HOME
CHARGER
PARAMETER
END VOLT
DISCHARGE
.
3.20V
Please touch “ ” and “ ” to get the proper parameter.
▲
▲
SETTING
T6755
T6755
17
16
OFF
100-20000 mAh
OFF
1-720 Min
1-120 min
20 C/68 F -
80 C/176 F
LiPo
Lilon
LiFe
4.18-4.3V/Cell
4.08-4.2V/Cell
3.58-3.7V/Cell
LiPo
Lilon
LiFe
NiMH
NiCd
Pb
3.0-3.3V/Cell
2.9-3.2V/Cell
2.6-2.9V/Cell
0.1-1.1V/Cell
0.1-1.1V/Cell
1.8V/Cell
ENTER
NEXT
SETTING
SAFETY
PROTECTION
ENTER
NEXT
SETTING
CHARGER
PARAMETER
SETTING
ABOUT
ABOUT
System information: model no., serial no., hardware version,
software version.
WARNING! By setting the TVC to any POSITIVE SETTING above default value, you ACCEPT ALL RESPONSIBILITY for
DAMAGE to your battery, FIRE, INJURY, and any other loss which may result. If you do not agree to accept all risk, DO
NOT OPERATE YOUR CHARGER UNLESS ALL TVC POSITIONS ARE SET TO DEFAULT VALUE!