Trigger housing remoVal

Position the shotgun on a clean surface with the trigger guard upward. With a blunt

object (no greater than 3/16” [4.76 mm] diameter), push out the small diameter trigger

housing retainer pin located on the side of the receiver, approximately a 1/2” (12.7 mm)

below the rear of the trigger guard (Fig. 8).

Remove the trigger housing assembly by lifting the rear portion upward first.

The trigger housing is a complex assembly and must not be disassembled.

Disassembly should only be performed at an authorized Product Service Center or

by a qualified gunsmith.

8

Do not pull the trigger and allow the hammer to fall when the trigger housing

assembly is removed from the receiver. To do so may result in personal injury

or damage to the assembly.