Section 8 – Miscellaneous Commands
Radiance Mini
rev 091211
27
On/Off Message
A programmable string can be sent to another device via the RS-232 connector to turn the device on or off.
The command is:
MENU → Other → OnOff Setup → (On Message, Off Message)
Message Control
This sets the RS-232 parameters that are used for sending a power on/off message to another device. The
command is:
MENU → Other → OnOff Setup → Message Ctl
Test Patterns
Warning:
Test patterns can burn plasma and CRT displays if left on for more then a few seconds.
The user can select from a large selection of test patterns. While in the test pattern menu the
and
arrows select a test pattern group. Press the “4” button to step though the test patterns in a group. For
many test patterns the intensity can be adjusted from 0 to 100 IRE, in 5 IRE steps, using the
and
arrows. Reference test patterns are only affected by the output PC/Video level setting. Adjustable patterns
allow viewing the effect of the output color management settings. The Warm Up test pattern displays a 20
IRE to 50 IRE gray screen.
To exit the test pattern command but leave the pattern on-screen, press “OK”. You can then adjust various
parameters to judge their effect on the pattern. Press “Prev” to then toggle between the source and the
pattern. Press “Alt” to jump back into the pattern command. The “Prev” and “Alt” functions are only valid
if leave the pattern on-screen by pressing “Ok”. The ten video inputs are numbered 1 to 10. For inputs 1
through 9, press the “Input” button and then press the corresponding number button on the remote. For
input 10, press the “Input” button, then the “0” button”. The command is:
MENU → Other → Test Pattern→ Pattern → (Reference, Adjustable, Warm up)
Remote Control
Allows changing the default command usage of the arrow buttons on the remote. By default the Up/Down
arrow buttons can be used to control zoom. The Right/Left arrow buttons can be used to select the input
aspect ratio. You can turn off these additional functions by selecting “Off”. The command is:
MENU→Other→I/O Setup→Remote Ctl→(Up/Down arrows, Rt/Left arrows)→(On, Off)
LED Setup
This command controls the operation of the Green LED on the front panel. The LED can be set to “Green” to
be a power on indicator or set to “Dark” so that it is off when the Radiance is operating. The command is:
MENU → Other→ I/O Setup → LED Setup → (Green, Dark)
RS-232 Setup
With echo on the Radiance will echo all characters sent to it. With echo off the Radiance will only send a
message at power on/off. With echo set to off with status, the power on/off messages are changed to
status responses. See Tech Tip 11 for delimiter usage and more details. The command is:
MENU → Other → I/O Setup → RS-232 Setup → (Echo, Delimiters) → (On, Off)
3D Glasses
NOTE: Generally 3D displays/projectors control the 3D glasses. In this case this command is not used.
These settings control the Lumagen 3D Eyeglass Adapter when it is connected the HDMI output on the
Radiance. The delay setting adjusts when the shutter-glasses switch eyes. If the 3D effect doesn’t look
correct it may be that the left and right eyes are swapped. Changing the polarity will correct this. The
command is:
MENU → Other → I/O Setup → 3D Glasses → (Delay, Polarity, Enable)