1-4
Switching Output Ratings
Electromechanical Relay Outputs:
5.0 Amperes @ 120VAC or 24VDC
AC Solid State Relay Outputs:
1.5 Amperes @ 240VAC
DC Solid State Relay Outputs:
3.0 Amperes @ 60VDC
General
Response Time, Die Protection
(static type, time from input change to E-Stop
relay contacts open):
25mS (typical), 33mS (maximum)
Response Time, Die Protection
(cycling type, time from window position
passed to E-Stop relay contacts open):
20mS (typical), 28mS (maximum)
Pulse width recognized by N.O. die protection
input (low pulse):
1mS minimum
Pulse width recognized by N.C. die protection
input (high pulse):
9mS minimum
Maximum Operating Speed:
2000 SPM
Maximum Ambient Temperature: