NOTE:

NEVER remove or install any card in the OmniLink 5000 when the power to the
control is on. Doing so can damage the control, the card, or both!

Figure 3.1: OmniLink 5000 Extended Card Rack

Section 3.

Installation

Section 3.1

Auto-Setup Module Installation

The 5000-10 Auto-Setup Module (ASM) installs in the OmniLink 5000 extended card rack. Figure 3.1
shows the location of the ASM in the last slot of the extended card rack. To remove the module, loosen
the knurled screws at the top and bottom of the board and use them to pull the board straight out of the
rack. To install, start the module in the card guide slots on the rack, push straight into the rack to firmly
seat the module, and tighten the knurled screws.

The face plate of the ASM is partitioned with labels such as “SS1", “AS1", etc. These labels represent
the type of module that can be installed on the card at that location. “SS1" and “SS2" can have slide
adjust modules installed. “AS1" through “AS4" can have air adjust modules (counterbalance and
cushion use the same control module) installed. Slide adjust cards are twice the width of air adjust
cards. Note that SS2 overlaps with AS1 and AS2 to allow a second slide adjust card to be installed in a
double action press at the expense of two air slots. “AS7" is used for hydraulic overload control and is
built in to the base card.

Each module is held on to the base card by four #6-32 screws. If not already assembled, install each
module on the base card putting slide adjust cards in SS1 or SS2 and air adjust cards in AS1, AS2, AS3,
or AS4. The plug in terminals on the modules should stick out of the faceplate of the base card.