beautypg.com

Lingenfelter L460105297 Lingenfelter LNC-003 Dual RPM Launch Controller v2.7 User Manual

Page 2

background image

Parts List

#

Part number

Description

1

LNC-003

LPE Dual RPM Launch Controller

1

72” trigger wire harness (part of PN LNC-003)

2

Hook & loop tape, 3.5” length

4

AV16037

Self-tapping screw

1

L450080000

Transient voltage suppression (TVS) diode kit

1

L950050000

LPE technician’s screwdriver

1

L920010000

LPE decal

1

Instructions

Optional Items

• Additional transient voltage suppression (TVS) diode

L450080000

• STOV-002 MPH activated switch

L460050000

• CTAP-001 Clutch and Throttle actuated position switch

L460190108

• CTAP Plug-And-Play harness for Corvette, Camaro & CTS-V

L480370108

• Sealed 40 amp heavy duty relay kit

L450100000

• LPE microswitch kit

L480330000

• LED for indicator light

• Red 12 vdc LED with 30 cm leads

L450030000

• Green 12 vdc LED with 30 cm leads

L450040000

• Red LED lighted paddle toggle switch, 20 amp

DC-7600500

• Connector, AMP Mate-N-Lock, Female 1-pos

571-14803490

• Connector, AMP Mate-N-Lock, Male 1-pos

571-14803510

• Connector, AMP Mate-N-Lock Pin, 24-18 AWG

571-606181

• Connector, AMP Mate-N-Lock Socket, 24-18 AWG

571-606171

Specifications:

Custom molded high temperature glass filled Nylon 6 enclosure with direct access to the controller

settings without requiring removal of a cover or access panel.

40 MHz 16-bit automotive qualified processor with eight channel Enhanced Time Module.

Each coil drive circuit has a dedicated timer to keep the timing accurate over the full RPM range.

Independent coil drive provides Sequential Ignition Kill when RPM limiting is active.

Reverse battery protection.

Both of the activation inputs have active clamps and optical isolation to suppress electrical noise

from external solenoids (such as trans brake and line lock).

Digital filter provided in software to further isolate electrical noise on the activation inputs.

Separate Primary and Secondary RPM x100 & RPM x1000 switches for easier setting adjustments.

RPM limiter activation point can be adjusted from 1500 to 9,900 RPM in 100 RPM increments.

Ground Activation and +12 Volt Activation inputs for the Primary RPM limit activation.

Dedicated +12 volt activation input for the Secondary RPM limiter.

True plug-and-play coil pack connection design for ease of installation and removal.

Fully encapsulated (potted) construction for added durability.

One year warranty (from date of purchase).

Page 1 of 17