Labconco Protector Controlled Atmosphere Glove Box User Manual
Page 56
Chapter 7: Accessorizing Your Glove Box
Product Service 1-800-522-7658
52
Part #
Descriptions
Electrical Receptacle & Plug Type
5121810
100-115 volts, 50/60 Hz
North America, 100-115 Volts
5121831
208-230 volts, 50/60 Hz
British (UK)
5121835
208-230 volts, 50/60 Hz
Schuko
5121840
208-230 volts, 50/60 Hz
China/Australia
5121845
208-230 volts, 60 Hz
North America, 208-230 Volts
9. AtmosPure Regeneration Plumbing Kit (Part #5441700)
The regeneration plumbing kit includes flexible tubing and fittings to
make all the regeneration service supply tubing connections. These
are the connections to the 4% hydrogen inert gas mixture, vacuum,
and vent.
10. AtmosPure Circulation Kits (see Part #’s below)
The circulation kits include all the plumbing and tubing parts needed
to connect the Gas Purifier to the glove box. There are two options
for neoprene lined hose or stainless steel tubing.
Part #
Description
Used On
5441800
3/4" I.D. Neoprene lined hose All Glove Boxes, single width
5441801
3/4" I.D. Neoprene lined hose All Glove Boxes, double width
5441802
3/4" Rigid Stainless Steel
Protector Glove Boxes, single width
5441803
3/4" Rigid Stainless Steel
Protector Glove Boxes, double width
11. AtmosPure Roughing Pre-Filter Kit (Part #5441500)
Provides two roughing particulate pre-filters and clamp plates to
mount inside Protector Glove Boxes only. It is used to filter the inlet
and outlet of the glove box as the inert gas is purified. Order
individual 5122400 filters separate. Two each required.
12. AtmosPure P100 Particulate Filter Kit (Part #5441600)
Provides two P100 particulate filters and mount housings that are
similar to respirator cartridges. P100 filters are 99.97% efficient for
all particulates. It is used to filter the inlet and outlet of the glove box
as the inert gas is purified. Order replacement filter set 5441601
separate which includes two P100 particulate filters.
13. Oxygen Monitors
Oxygen monitors allow the user to continuously monitor oxygen
levels inside the glove box. Monitors are normally placed inside the
main chamber to provide the best performance. Never operate a
transfer chamber vacuum evacuation on sensitive oxygen
monitors as damage can occur.
Part #
Descriptions
5244500
0-10,000 ppm Oxygen Monitor (with three ranges of 0-100 ppm, 100-
1,000 ppm, and 1,000-10,000 ppm) 100V/115V – 50/60 Hz
5244501
0-10,000 ppm Oxygen Monitor (with three ranges of 0-100 ppm, 100-
1,000 ppm, and 1,000-10,000 ppm) 230V – 50/60 Hz – International
5244400
0.1-100% Oxygen Monitor (1,000 ppm lowest) 100V/115V/230V –
50/60 Hz