beautypg.com

Installation, Venting installation, Continued – Desa VDVF36PN/PP User Manual

Page 16

background image

105706-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

16

INSTALLATION

WALL SWITCH INSTALLATION

Since the VDVF36 series models use a valve that operates on
millivolt current generated by the pilot, a wall switch may be used
to activate the gas control valve without the use of normal household
electricity.

1.

To remove the louvers, simultaneously pull both top end spring
latches towards the center of the appliance until they are dis-
engaged from locating holes. Repeat for bottom end spring
latches and pull outward. Reverse the procedure to install lou-
vers back onto the appliance (see Figure 32).

Figure 32 - Removing Louver

Glass

Locating
Holes

Spring
Latch

VENTING INSTALLATION

Continued

D1000

7" x 12" Galvanized Coaxial Pipe (6 pcs.)

D1010

7" x 24" Galvanized Coaxial Pipe (6 pcs.)

D1020

7" x 48" Galvanized Coaxial Pipe (6 pcs.)

D1030

7" Adjustable (7-12") Galvanized Coaxial Pipe
(6 pcs.)

D1050

7" x 6" Galvanized Coaxial Pipe (6 pcs.)

D2000

7" x 90° Elbow (6 pcs.)

D2010

7" x 45° Elbow (6 pcs.)

D2060

7" x 45° Starter Elbow

D3000

Wall Strap/Offset Support (6 pcs.)

D3010

Storm Collar (6 pcs.)

D3020

Wall Thimble (6 pcs.)

D3050

Vertical Restrictor (6 pcs.)

D3060

Ceiling Firestop/Support (6 pcs.)

D3070

Rectangular Horizontal Rigid Vent Termination Cap

D3090

Cathedral Ceiling Support Box

D4000

Roof Flashing 6/12-9/12

D4010

Roof Flashing 9/12-12/12

D4020

Flex Connector (6 pcs.)

D4030

Flex Wall Thimble (6 pcs.)

D4040

4" Hose Clamp (6 pcs.)

D4050

7" Hose Clamp (6 pcs.)

D5000

Vinyl Siding Standoff (6 pcs.)

Simpson Dura-Vent GS 4" x 6

5

/

8

"

Number Description
902

7" x 48" Pipe

903

7" x 36" Pipe

904

7" x 24" Pipe

906

7" x 12" Pipe

907

7" x 9" Pipe

908

7" x 6" Pipe

Vanguard Flexible Venting

Number Description

FGFVK

Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 4' Flexible Pipe, 4" x 4'
Flexible Pipe, Wall Thimble, Horizontal Termination,
(4) Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose
Clamps, RTV Silicone, and 10 Screws

D1040

7" x 25' Coaxial Flex Pipe with Spacer Springs

D3080

Rectangular Horizontal Flex Termination Cap

Vanguard Rigid Venting

(Cont.)

Number Description

VENTING INSTALLATION

Parts Lists for Venting Kits and Components (Cont.)

INSTALLATION

Wall Switch Installation

911

7" Adjustable (11"-14

5

/

8

") Pipe

940

Wall Thimble

941

Cathedral Ceiling Support Box

943

Roof Flashing 0/12-6/12

943S

Roof Flashing 7/12-12/12

945

7" x 45° Elbow

950

Vinyl Siding Standoff

953

Storm Collar

963

Ceiling Firestop

981

36" Snorkel Termination

984

Horizontal Termination Vent Cap

988

Wall Strap

990

7" x 90° Elbow

991

Vertical High Wind Termination

Simpson Dura-Vent GS 4" x 6

5

/

8

"

(Cont.)

Number Description

This manual is related to the following products: